APPLIED & ELECTRONICS INSTRUMENTATION
SEM-V, 2011-12
B.TECH EXAMINATION
UTTARAKHAND TECHNICAL UNIVERSITY
utu question paper
Time: 3 Hours
Total
Marks: 100
Attempt any four parts:
- Explain the following terms with suitable example and
graph:
(a) Accuracy and Precision
(b) Dead time and Dead zone
(c) Sensor and Actuator - What are the input test signals and give the dynamic
characteristics for the first order system with suitable example?
- Why Sensitivity and Linearity are the two conflicting
requirements in a resistive potentiometer?
- Two plates of parallel plate capacitive transducer are
30 mm apart and the space is filled with two different dielectric materials,
one material is 1 cm thick with dielectric constant of 10, if the
capacitive transducer were to be made with single dielectric material,
what is the dielectric constant of that material?
- A strain gauge has a gauge factor of 4. If the strain
gauge is attached to a metal bar that stretches from 0.25 to 0.255 mm when
strained, what is the percentage change in resistance? If the unstrained
value of gauge factor is 120Ω, what is the resistance value of gauge
factor after application of strain?
- Design the Wheatstone bridge arrangement employed for
the measurement of Strain for the Quarter Bridge, Half Bridge and Full
Bridge with respective sensitivity.
Attempt any four parts:
- Describe the Load cell with constructional feature of
Ring type load cell and show how their output signals enable further
processing for indication.
- Describe the method of measurement of differential
pressure using inductive type transducer and differentiate between
Absolute, Gauge and Differential pressure referred in this case.
- A resistive Transducer with a resistance of 5 KΩ and a
shaft distance is 5 inch is used in arrangement as shown in figure.
Potentiometer R3-R4 is also 5K and V is 5V. The
initial position to be used as reference point is such that R1=R2.
At the start of the test, Potentiometer R3- R4 is
adjusted so that the bridge is balanced (Vo=0). Assuming that
the object being monitored moves a max. Resistance of 0.5 inch toward A.
What will be the new value of Vo?
- An LVDT has an output of 6V when the displacement is
0.4 x 10-3 mm. Determine the sensitivity of this instrument in
V/mm. A 10V voltmeter with 100 scale divisions is used to read the output.
Two tenth of a division can be estimated with ease. Determine Resolution
of the voltmeter.
The above arrangement is used in pressure transducer for measuring the deflection of diaphragm. The diaphragm is deflected through 0.5 x 10-3 mm by a pressure of 1000 N/m2. Determine the sensitivity and resolution of this instrument? - Explain the principle working of thermistor, its
relation with temperature and its characteristics.
- The EMF of an Iron-Constantan thermocouple is to be
measured by the potentiometer shown in fig. a potential difference of
1.0186 V is applied over point A&B. The current through the resistor
is 2mA and the range of temp. Measurement is 250- 850o C.
Calculate R1, R2 and R3 for ambient temp
20o C. The EMF of iron-constantan couple with reference
junction at 0o C is 1.019 mV at 20o C, 13.553 mV at
250o C and 48.176 mV at 850o C.
Attempt any two parts:
- (a) Which
one method is mostly preferred for vibration measurement and why? And
explain its working with proper diagram and its magnitude and phasor
graph?
(b) Explain the piezoelectric Accelerometer with its neat and clean Schematic diagram and its features. - What is the basic function of the Tachometer and
describe the working principle of A.C Tachometer and its advantages?
- What do you understand by Shaft-Torque? Explain the
principle working of the Strain Gauge Torque meter with its functional
diagram.
Attempt any two parts:
- (a) What
is the basic concept of the Earth Ground and how can we reduce the noise
introduced by Ground loops and Inductive coupling?
(b) A measurement system uses a resistance strain gauge for measurement of pressure. The strain gauge has an unstrained resistance of 120Ω and is connected in one arms of the bridge. The other three arms of the bridge have each a resistance of 120Ω the temperature is 3000 K the bandwidth is 100 KHz. The output of the bridge is a voltage signal.
(i) When a pressure of 7000 kN/m2 is applied the output voltage is 0.12 mV. Find the ratio of the output (signal) voltage to the noise voltage generated by the resistor. Also comment on the effect of noise over signal and its interference.
(ii) Find the ratio of the output signal voltage to noise voltage if the pressure is 7 kN/m2. Also comment on the resulting effect of noise and interference? - (a) In order to measure noise figure of an amplifier, a
noise voltage that is 10% of the signal voltage that is 10% of the signal
voltage is applied at the input of the amplifier. The noise voltage at the
output of the amplifier is 20% of the signal voltage. Calculate the noise
figure of the amplifier.
(b) What is the difference between Radio telemetry and radio communication and explain the FM/FM ratio telemetry scheme? - How can we measure the liquid pressure placed in a
beaker by PWM telemetry scheme? Explain with its functional block diagram
and waveforms.
Attempt any two parts:
- (a) Describe the functional behavior of chopper in D.C.
Electronic Voltmeter with its working diagram.
(b) Twenty one data channels, with sub carrier center frequency ranging from 400 Hz to 165 KHz have been designated for telemetry use. All have a frequency deviation of ±7.5%. Assuming modulation index of 5, obtain intelligence bandwidth of channel first for a center frequency of 70 KHz. Assuming that frequency division have been used. - What factors discriminate the Electronic Wattmeter from
dynamometer type Wattmeter and explain the working of Analog Electronic
Wattmeter with schematic diagram.
- (a) Describe the working principle of the Integrating type
Digital voltmeter with suitable diagram and Waveform Representation.
(b) What method should be preferred for the measurement of frequency? Describe it with proper functional diagram.
---------------------------------
1 comment:
It is important to determine what kind of load cell to use for any tool that needs measurement. Afterall, this device will be your indicator. This examination is undeniably one of the difficult technical and mechanical tests to solve.
Post a Comment